Setting Alert Detail Criteria For Server Manager Alerts
When setting alert detail criteria for alerts originating from the Server Manager, specific string values can be set.
String Values
The following values are valid when entering Details Text for Server Manager alerts. The operator value is usually set to equal to ‘=’.
Details Text | Valid Details Value |
---|---|
Event Type | Error, Audit Success, Information, Warning |
Source | Halcyon SNMP Manager |
Category | No specific value required |
Event ID | Any valid Event ID number |
User | No specific value required |
Message | Any valid message is displayed in the Windows Event Log. The use of wildcards is recommended. |
- Details Text: Event Type
- Details Value: = Error
- Details Text: Event ID
- Details Value: = 125
- Details Text: Message
- Details Value: = *Service: esInterface failed: NetMan*
In the above example, an alert is generated for any Server Manager Event Type with a value of error, that also passes other specified criteria.