Windows Lawson ServerView Monitoring template
The Windows Infor ServerView Monitoring template includes monitors for Infor ServerView solutions and uses Web Application, File and Folder, Service and TCP HTTP monitoring components.
NOTE: If you have not purchased the Web Application Monitor, this template only includes the File and Folder, Service and TCP HTTP elements.
The Windows Infor ServerView Monitoring template contains the following components:

Contains the following rules:
- Checking for looping M3 auto job - URL(http://127.0.0.1:6788/showlog?addr=127.0.0.1&port6101) Timeout(5 Secs) TriggerType(first Matching) TriggerObject(Table) TriggerObject(Table)
- Excessive CPU - URL(http://127.0.0.1:6666/) Timeout(15 Secs) TriggerType(Each Matching) TriggerObject(Row)
- High severity for NEWS page - URL(http://127.0.0.1:6666/news) Timeout(5 Secs) TriggerType(Each Matching) TriggerObject(Row)
- Instances of an interactive job for a specified user - URL(http://127.0.0.1:6666/) Timeout(15 Secs) TriggerType(Each Matching) TriggerObject(Row)
- Interaction auto job validation - URL(http://127.0.0.1:6666/) Timeout(15 Secs) TriggerType(First Matching) TriggerObject(Row)
- Interactive job CPU% Check - URL(http://127.0.0.1:6666/) Timeout(15 Secs) TriggerType(Each Matching) TriggerObject(Row)
- ServerView Counters Check - URL(http://127.0.0.1:6666/) Timeout(15 Secs) TriggerType(First Matching) TriggerObject(Row)
- ServerView Dumplogs in NEWS page - URL(http://127.0.0.1:6666/news) Timeout(5 Secs) TriggerType(Each Matching) TriggerObject(Row)
- ServerView Status Check - URL(http://127.0.0.1:6666/) Timeout(15 Secs) TriggerType(Each Matching) TriggerObject(Row)
- Supervisor Check - URL(http://127.0.0.1:6666/) Timeout(25 Secs) TriggerType(First Matching) TriggerObject(Table)
- Transaction Server Check - URL(http://127.0.0.1:6666/) Timeout(25 Secs) TriggerType(First Matching) TriggerObject(Table)
(*Only available if a Web Application Monitor license has been purchased separately).

Contains the following rule:
- Alert if SalesCube is not updated overnight - Path(D:\) TriggerOn(First Matching Matching File Or Folder) SubFolders (True) Thresholds(Modified)

Contains the following rules:
- Backup Exec Services Started - Service(Backup Exec Remote Agent for Windows Systems) Status(<>’Running’)
- M3 Enterprise Collaborator (MEC) Service Started - Service(MECServer) Status(<>’Running’)
- MapGenServer Service Stared - Service(MapGenServer) Status(<>’Running’)
- OpenText® StreamServe Repository Server Service Started - Service(StreamServe Repository Server) Status(<>’Running’)
- OpenText® StreamServe Service Started - Production Environment - Service(StreamServe Prod) Status(<>’Running’)
- OpenText® StreamServe Service Started - Standard Environment - Service(StreamServe zSTD) Status(<>’Running’)
- OpenText® StreamServe Service Started - Test Environment - Service(StreamServe Test) Status(<>’Running’)
- Print Spooler Service Started - Service(Print Spooler) Status(<>’Running’)

Contains the following rule:
- Check CONNECT Site - URL(http://127.0.0.1:8780/) Timeout(5 Secs) Include(‘News’) NotInclude(‘404’)
NOTE: All actions for each of the above rules within this template are set to a default of sending an alert to the Enterprise Console. You must manually change this setting if you require an alternative action to be taken upon the generation of an alert.