Work with Security Alerts (WRKCCALR)
The WRKCCALR command allows authorized users to configure and view the Security Alerts settings.
1/21/09 Work with Security Alerts QSECOFR 9:15:28 CRRM090
Type options, press Enter. 2=Change 4=Remove 5=Display
Audit Seq To To Message To Message Opt Category Nbr Action User Queue Name Queue Lib __ *AUTH 001 *USER QSECOFR __ *DEK 001 *EMAIL __ *FLDREG 001 *QHST __ *MEK 001 *EMAIL __ *MEK 002 *QHST
F3=Exit F5=Refresh F6=Add F12=Cancel
|
Screen Example: WRKCCALR Command with Sample Values
The following users can use this command:
- QSECOFR user profile (unless excluded in the Key Officer settings)
- A user profile with *SECADM authority (unless excluded in the Key Officer settings)
- A Key Officer that has a *YES specified for the “Maintain key policy and alerts” authority setting
How to Get There
From the Key Policy and Security Menu, choose option 3, Work with Security Alerts. Or, execute the command of CRYPTO/WRKCCALR.
Options
For each Alert listed on the screen, you can use one of the following options.
Option | Description |
---|---|
2 | Displays a prompt to change the settings for the Alert using the CHGCCALR command |
4 | Displays a prompt to confirm the deletion of the Alert using the DLTCCALR command |
5 | Displays the current settings for the Alert using the DSPCCALR command |
Screen Function Keys
Listed below are the function keys you can utilize within the WRKCCALR screen.
Fnctn | Description |
---|---|
F3 | Exits the WRKCCALR screen |
F5 | Refreshes the list of Alerts |
F6 | Displays a prompt to add a new Alert using the ADDCCALR command |