SNMP - Get Bulk |
<AMSNMPGETBULKREQUEST HOST="text" COMMUNITY="text" SNMPVERSION="text (options)" RESULTDATASET="text" NONREPEATERS="number" MAXREPETITIONS="number" VARBINDNAMES="text" /> |
Description: Issues a GETBULK message to an SNMP agent in order to inspect a group of variables in a single transaction. This activity is particularly useful for retrieving large tables. The GETBULK operation performs a GETNEXT operation for the first number of variable bindings in the request and performs a GETNEXT operation (continuous) for each of the remaining variable bindings in the request list. Note that the SNMP GETBULK command is not supported on devices using SNMPv1.
IMPORTANT: To get the most out of SNMP activities, users should have a fundamental understanding of SNMP architecture and its major elements, such as Managers, Agents, MIBs, and PDUs. |
Used to get data on a bulk amount of variables.
General
Property |
Type |
Required |
Default |
Markup |
Description |
Agent IP Address |
Text |
Yes |
(Empty) |
HOST="xxx.xxx.xxx.xxx" |
The IP Address or host name of the SNMP agent to communicate with. |
Return variable for the first variable binding |
Number |
Yes |
(Empty) |
NONREPEATERS="3" |
The number of variables in the variable list for which a simple GETNEXT operation will initially be performed. This is similar to the Non-repeaters value. |
Max number of variables to be returned for the rest of the variable bindings |
Number |
Yes |
(Empty) |
MAXREPETITIONS="3" |
The maximum amount of GETNEXT operations for the rest of the variables. This is similar to the Max-Repetitions value. |
Community |
Text |
Yes |
Public |
COMMUNITY="netauto" |
The SNMP community name. |
Create and populate dataset |
Text |
Yes |
(Empty) |
RESULTDATASET="myData" |
The name of the dataset to create and populate with the results of the request. |
Advanced
Property |
Type |
Required |
Default |
Markup |
Description |
Timeout after |
Text |
Yes |
30 |
TIMEOUT="500" |
The total elapsed time that this activity should wait for a response before generating a timeout error. The default is 30 seconds. |
Timeout measure |
Text (options) |
Yes |
seconds |
|
The time measurement that corresponds to the value entered in the Timeout after parameter. The available options are:
|
Broadcast delay |
Number |
No |
3 |
BROADCASTDELAY="10" |
The maximum broadcast delay time that this activity will allow. The default is 3 seconds. |
Broadcast measure |
Text (options) |
No |
seconds |
|
The time measurement that corresponds to the broadcast delay value. The available options are:
|
SNMP version |
Text (options) |
No |
SNMPv1 |
|
The version of the SNMP protocol to use. The default is SNMP version 1 as it is the most prevalent. The available options are:
|
Remote port |
Number |
No |
161 |
REMOTEPORT="555" |
The TCP/IP port that should be used for the SNMP request. The default port is 161. |
Data
Property |
Type |
Required |
Default |
Markup |
Description |
Variable name |
Text |
Yes |
(Empty) |
VARBINDNAMES="1.3.6.1.2.1.2.2.1.1.1" |
Variable bindings are entered in the Data Bindings tab. To add a variable name, click the Add button. This will present a dialog titled Define variable binding in which the proper variable(s) can be entered. Added variable bindings are displayed in the Variable name parameter. To edit a variable, highlight it from the list and click Edit. To delete an existing variable, highlight the variable and click Delete. |
Use string notation for OIDs |
Yes/No |
No |
Yes |
OIDSTRINGNOTATION="no" |
Specifies whether the variable should contain the returning OID in numeric or "human readable" format. If set to YES, the value will be returned in human readable format. If set to NO, the value will be returned in numeric format. This parameter is set to YES by default. |
Use string notation for timetick values |
Yes/No |
Yes |
Yes |
TIMETICKSTRINGNOTATION="no" |
Timetick variable types are normally a 32-bit number but they can be returned in string notation. If this parameter is set to YES, the step will return the value in string notation. If set to NO, this step will return the value in 32-bit number format. This parameter is set to YES by default. |
A percent sign is used as a special character to indicate the beginning and end of an expression. This allows variables, functions and other expressions to be entered in any text parameter of a task's properties. For example: %1+1% inside a task will resolve to 2 at runtime. A more elaborate example is %FileDateTime(myFile)% which results to the date/time of myFile. To help construct expressions, you can open Expression Builder by clicking the Insert Expression (%) button or by pressing F2.
More on the expression builder
NOTE: The code below can be copied and pasted directly into the Steps pane of the Task Builder. |
Description: Send SNMP Get Bulk message to "192.168.110.133" with 3 non-repeater(s) and a max repetition of 3. Variable bindings are "1.3.6.1.2.1.2.2.1.1.1". Create and populate dataset "theDataset" with results. Community is "public". Use SNMP version "snmpv2c" to send the message.
<AMSNMPGETBULKREQUEST HOST="192.168.110.133" COMMUNITY="public" SNMPVERSION="snmpv2c" RESULTDATASET="theDataset" NONREPEATERS="3" MAXREPETITIONS="3" VARBINDNAMES="1.3.6.1.2.1.2.2.1.1.1" /> |